I had a random misfire because the flange on the test pipe was not seated properly on the headers. allowing outside air to hit the sensor -B1S1. The sensor reads
|
|||||||
|
|
LinkBack | Thread Tools | Display Modes |
|
|
#7 (permalink) |
|
Track Member
Join Date: Jul 2011
Location: Edmonton, Canada
Posts: 681
Drives: BOOSTED3-7-0
Rep Power: 16 ![]() ![]() ![]() ![]() |
I had a random misfire because the flange on the test pipe was not seated properly on the headers. allowing outside air to hit the sensor -B1S1. The sensor reads lean, dumps fuel to compensate, this causes the ecm to pop a misfire code.
After I fixed the leak, the code cleared itself on the 3rd startup.